Skip to Content

EDFA Card for DCI Chassis

https://nexgen1.odoo.com/web/image/product.template/10527/image_1920?unique=9931463

The EDFA Card for DCI Chassis is a fixed-gain erbium-doped fibre amplifier board that compensates signal power loss across the transmission link. It amplifies up to 48 channels at 100GHz spacing or 96 channels at 50GHz spacing in the C-band, with flat gain and low noise figure. Available with one or two EDFA stages, an optional built-in OSC monitoring channel, and an optional VOA.

Multi-channel C-band amplification

Amplifies up to 48 channels at 100GHz spacing or 96 channels at 50GHz spacing simultaneously, with flat gain across the band.

One or two EDFA stages

The same card supports a single amplification stage or two stages on one card, each independently set to 17, 20, 25 or 30dB rated gain.

Configurable OSC and OTDR monitoring

A single ordering code sets no monitoring, 1- or 2-direction OSC at 1510nm/1.25Gb/s, 1- or 2-direction OTDR, or both together, for DCN communication and fibre-fault localisation.

Optional VOA per stage

Network-managed variable optical attenuator ahead of each EDFA input, 0–20dB adjustment range, <1dB intrinsic insertion loss.

Standard monitor port, optional OTDR port

Built-in MON port (21–23dB tap ratio vs. the main channel) is standard; an OTDR measurement port is optional, one per line interface.

Compact single-slot footprint

A single-slot card compatible with the OTN DCI platform range.

SIG(BA-IN) BA LINE(BA-OUT) LINE(PA-IN) PA SIG(PA-OUT) OSC-AD OSC MON(PA-OUT) MON(BA-OUT) OTDR(BA-OUT) OTDR(PA-IN)
CARD FOR DCI CHASSIS1 SLOT

0.00 kr 0.0 DKK 0.00 kr

  • EDFA Configuration
  • Secondary EDFA Configuration
  • VOA
  • Monitoring

This combination does not exist.

Optical
Channel CountUp to 48 channels @100GHz or 96 channels @50GHz, C-band
EDFA
Configuration1 or 2 built-in EDFA stages, each independently set to a rated gain of 17, 20, 25 or 30dB
Parameters by Rated Gain
Specification17dB20dB25dB30dB
Wavelength Range1528–1568nm1528–1568nm1528–1568nm1528–1568nm
Gain Range14–20dB17–23dB22–28dB27–33dB
Maximum Total Output Power≥20dBm≥20dBm≥20dBm≥20dBm
Noise Figure<6.0dB (nominal gain)<6.0dB (nominal gain)<5.5dB (nominal gain)<5.5dB (nominal gain)
Gain Flatness<1.5dB<1.5dB<1.5dB<1.5dB
Polarization Dependent Loss<0.5dB<0.5dB<0.5dB<0.5dB
Input Power Detection Range-23 to 8dBm-23 to 8dBm-31 to 0dBm-36 to -5dBm
Output Power Detection Range-6 to 20dBm-6 to 20dBm-6 to 20dBm-6 to 20dBm
Reflection Coefficient<-30dB<-30dB<-30dB<-30dB
Gain Stability±0.5dB±0.5dB±0.5dB±0.5dB
OSC & OTDR Monitoring Port
ConfigurationOptional, independently configurable OSC (1- or 2-direction) and/or OTDR (1- or 2-direction) monitoring port - see Ordering Information for the available combinations
OSC Wavelength / Rate1510nm / 1.25Gb/s
VOA
ConfigurationOptional, one VOA per EDFA stage, positioned before each EDFA input
Intrinsic Insertion Loss< 1dB
Adjustment Range0–15dB
Power-Down StateInherent insertion loss (fail-safe pass-through)
Monitoring
MON PortStandard, optical power difference vs. main channel 21–23dB
Mechanical
Slots Occupied1 (compatible with the OTN DCI platform range)
NameEDFA Card for DCI Chassis
DescriptionEDFA optical amplifier board, 1 slot. Fixed-gain erbium-doped fibre amplifier compensating signal power in the transmission link; amplifies channels across the C-band with flat gain and low noise figure. Available with 1 or 2 EDFA stages, each independently set to 17, 20, 25 or 30dB rated gain, a standard MON port, optional VOA, and an ordering code selecting the OSC (1510nm/1.25Gb/s) and OTDR monitoring port configuration.
Part NumberDCI-EDFA-{EDFA1 Gain}[-{EDFA2 Gain}][-V]-{Monitoring Code}-1S
{EDFA1 Gain}Rated gain of the first EDFA stage, in dB: 17, 20, 25 or 30, required
[-{EDFA2 Gain}]omitted for a single-stage card · present for a dual-stage card, same value set as {EDFA1 Gain}
Dual-stage pairs offered
17+17 · 20+20 · 25+25 · 30+30 (matched pairs)
17+25 · 17+30 · 20+25 · 20+30 · 25+30 (mixed pairs)

The 17+20 pairing is not offered. Order is not significant (17+25 = 25+17); list the lower value as {EDFA1 Gain}.

[-V]omitted = without VOA · present = with VOA (one per EDFA stage)
{Monitoring Code}OSC and OTDR monitoring port configuration, required:
CodeConfiguration
NNo OSC, no OTDR
S1OSC, 1-direction · no OTDR
S2OSC, 2-direction · no OTDR
ST1OSC and OTDR, both 1-direction
ST2OSC and OTDR, both 2-direction
T1No OSC · OTDR, 1-direction
T2No OSC · OTDR, 2-direction